植體品牌  植體 - Internal    衛署醫器輸字第019542號



 

植體品牌

植體品牌-internal植體圖示

原廠網站(內六角植體系統目錄):
https://vsr.biohorizons.com/GetDocument?DocumentID=29063
 

 

BIOHORIZONS 植體品牌 線上諮詢

*加LINE諮詢 : @hlb4651c

*加LINE連接 : https://goo.gl/k97R2E

BioHorizons美國植體品牌  植牙課程  植牙論文  植體產品諮詢

植體品牌

植體相關論文

相關學術文章:
Maintaining inter-implant crestal bone height via a combined platform-switched, Laser-Lok® implant/abutment system: A proof-of-principle canine study.

作者:M Nevins, ML Nevins, L Gobbato, HJ Lee, CW Wang, DM Kim.
出處:Int J Periodontics Restorative Dent , Volume 33, Number 3, 2013

摘要:
ABSTRACT

Interimplant papillae are critical to achieving esthetic implant-supported restorations in the maxillary esthetic zone. Stable papillary anatomy, however, depends upon a stable volume of underlying crestal bone for support. Multiple studies have documented a critical interimplant distance of 3 mm, under which crestal bone resorption occurs. The current preclinical proof-of-principle canine study examines a novel implant-abutment system design, combining platform switching with precisely configured laser-ablated abutment and implant microgrooves to maintain interimplant crestal bone at interimplant distances of 2 and 4 mm. Results of this initial preclinical study suggest that it is possible through precise implant/abutment design modifications to place adjacent implants at distances of 2 to 4 mm without inducing subpapillary crestal bone loss.


載入全文   

 

相關學術文章:
Radiographic analysis of crestal bone levels around Laser-Lok collar dental implants.

作者:CA Shapoff, B Lahey, PA Wasserlauf, DM Kim.
出處:Int J Periodontics Restorative Dent. 2010;30:129-137

摘要:
INTRODUCTION

This retrospective radiographic study was organized to evaluate the clinical efficacy of implants with Laser-Lok microtexturing (8- and 12-μm grooves). A physical attachment of connective tissue fibers to the Laser-Lok microtexturing on the implant collar has been previously demonstrated using human histology, polarized light microscopy, and scanning electron microscopy. This analysis of 49 implants demonstrated a mean crestal bone loss of 0.44 mm at 2 years postrestoration and 0.46 mm at 3 years. All bone loss was contained within the height of the collar, and no bone loss was evident to the level of the implant threads. The radiographic evaluation of the clinical application of this implant supports previous findings that establishing a biologic seal of connective tissue fibers around a dental implant may be clinically relevant.

植體論文
 載入全文   

 

線上諮詢 食藥署核准仿單  

 

植體相關資訊

 
BilerChildrenLeg og SpilAutobranchen