美國植體品牌 - Clinical evaluation of laser microtexturing 

植體品牌

牙科植體

學術文章:
Clinical evaluation of laser microtexturing for soft tissue and bone attachment to dental implants.

作者:
GE Pecora, R Ceccarelli, M. Bonelli, H. Alexander, JL Ricci.

出處:
Implant Dentistry. Volume 18(1). February 2009. pp. 57-66.

摘要:

INTRODUCTION
A tapered dental implant (Laser-Lok [LL] surface treatment) with a 2 mm wide collar, that has been laser micromachined in the lower 1.5 mm to preferentially accomplish bone and connective tissue attachment while inhibiting epithelial downgrowth, was evaluated in a prospective, controlled, multicenter clinical trial.
 
MATERIALS
Data are reported at measurement periods from 1 to 37 months postoperative for 20 pairs of implants in 15 patients. The implants are placed adjacent to machined collar control implants of the same design. Measurement values are reported for bleeding index, plaque index, probing depth, and crestal bone loss.
 
RESULTS
No statistical differences are measured for either bleeding or plaque index. At all measurement periods there are significant differences in the probing depths and the crestal bone loss differences are significant after 7 months (P<0.001). At 37 months the mean probing depth is 2.30 mm and the mean crestal bone loss is 0.59 mm for LL versus 3.60 and 1.94 mm, respectively, for control implant. Also, comparing results in the mandible versus those in the maxilla demonstrates a bigger difference (control implant - LL) in the mean in crestal bone loss and probing depth in the maxilla. However, this result was not statistically significant.
 
DISCUSSION
The consistent difference in probing depth between LL and control implant demonstrates the formation of a stable soft-tissue seal above the crestal bone. LL limited the crestal bone loss to the 0.59 mm range as opposed to the 1.94 mm crestal bone loss reported for control implant. The LL implant was found to be comparable with the control implant in safety endpoints plaque index and sulcular bleeding index. There is a nonstatistically significant suggestion that the LL crestal bone retention superiority is greater in the maxilla than the mandible.     
植牙論文
    載入全文    

BioHorizons美國植體品牌  植牙課程  植牙論文  植體產品諮詢

植體品牌

牙科植體論文分類


植牙論文


Maintaining inter-implant crestal bone height via a combined platform-switched, Laser-Lok® implant/abutment system: A proof-of-principle canine study.

作者:M Nevins, ML Nevins, L Gobbato, HJ Lee, CW Wang, DM Kim. 
出處:Int J Periodontics Restorative Dent , Volume 33, Number 3, 2013


植牙論文


Radiographic analysis of crestal bone levels around Laser-Lok collar dental implants.

作者:CA Shapoff, B Lahey, PA Wasserlauf, DM Kim.
出處:Int J Periodontics Restorative Dent. 2010;30:129-137


 

植牙論文



The impact of loads on standard diameter, small diameter

 

作者:Allum SR, Tomlinson RA, Joshi R.

出處:Clin. Oral Impl. Res. 2008 May;19(6):553-559.


植牙論文



Mechanical basis for bone retention around dental implants

 

作者:H Alexander, JL Ricci, GJ Hrico.

出處:J Biomed Mater Res B Appl Biomater. Volume 88B, Issue 2, Pages 306-311, Feb 2009


植牙論文



Marginal tissue response to different implant neck design

 

作者:HEK Bae, MK Chung, IH Cha and DH Han.

出處:
Yonsei University College of Dentistry, Seoul, South Korea
J Korean Acad Prosthodont. 2008 Dec;46(6):602-609.


植牙論文



Interactions between MC3T3-E1 cells and textured Ti6Al4V surfaces

 

作者:Soboyejo WO, Nemetski B, Allameh S, Marcantonio N, Mercer C, Ricci J. 

出處:J Biomed Mater Res. 2002 Oct; 62(1):56-72


 

植牙論文



A bone-quality based implant system First year prosthetic loading


作者:Misch CE, Dietsh-Misch F, Hoar J, Beck G, Hazen R, Misch CM. 

出處:J Oral Implantol. 1999;25(3):185-197


植牙論文



Five-year prospective study of immediateearly loading of fixed prostheses in completely edentulous jaws with a bone quality-based implant system

作者:Misch CE, Degidi M.

出處:Clin Implant Dent Relat Res. 2003 May;5(1):17-28


植牙論文



Influence of thin mucosal tissues on crestal bone stability around implants

with platform switching a 1-year pilot study

作者:Linkevicius T, Apse P, Grybauskas S, Puisys A.

出處:J Oral Maxillofac Surg. 2010 Sep; 68(9): 2272-7.


植牙論文



Influence of Laser-Lok® surface on immediate functional loading of implants in single tooth replacement a 2-years prospective clinical study.

作者:D Farronato, F Mangano, F Briguglio, V Iorio Siciliano, R Guarnieri. 

出處:Submitted for publication, Int J Periodontics Restorative Dent.


植牙論文



Clinical evaluation of laser microtexturing for soft tissue and bone attachment to dental implants.

作者:GE Pecora, R Ceccarelli, M. Bonelli, H. Alexander, JL Ricci.

出處:Implant Dentistry. Volume 18(1). February 2009. pp. 57-66.


 

植牙論文

Histologic evaluation of a provisional implant retrieved from man 7 months after placement in a sinus augmented with calcium sulphate a case report.

作者:G Iezzi, E Fiera, A Scarano, G Pecora, A Piattelli.

出處:Journal of Oral Implantology. Volume 33, No. 2. 2007.


植牙論文

Immediate implant placement and provisionalization—two case reports.

作者:SJ Froum, SC Cho, H Francisco, YS Park, N Elian, D Tarnow.

出處:Pract Proced Aesthet Dent 2007;19(10):421-428

 

 

 

 

BioHorizons台灣植體代理