The impact of loads on standard diameter, small diameter and mini implants: A comparative laboratory study

作者:Allum SR, Tomlinson RA, Joshi R.
出處:Clin. Oral Impl. Res. 2008 May;19(6):553-559.

摘要:
ABSTRACT

Objectives: 
While caution in the use of small-diameter (≤3.5 mm) implants has been advocated in view of an increased risk of fatigue fracture under clinical loading conditions, a variety of implant designs with diameters <3 mm are currently offered in the market for reconstructions including fixed restorations. There is an absence of reported laboratory studies and randomized-controlled clinical trials to demonstrate clinical efficacy for implant designs with small diameters. This laboratory study aimed to provide comparative data on the mechanical performance of a number of narrow commercially marketed implants.
 
Materials and Methods:
Implants of varying designs were investigated under a standardized test set-up similar to that recommended for standardized ISO laboratory testing. Implant assemblies were mounted in acrylic blocks supporting laboratory cast crowns and subjected to 30° off-axis loading on an LRX Tensometer. Continuous output data were collected using Nexygen software.
 
Results:
Load/displacement curves demonstrated good grouping of samples for each design with elastic deformation up to a point of failure approximating the maximum load value for each sample. The maximum loads for Straumann (control) implants were 989 N (±107 N) for the 4.1 mm RN design, and 619 N (±50 N) for the 3.3 mm RN implant (an implant known to have a risk of fracture in clinical use). Values for mini implants were recorded as 261 N (±31 N) for the HiTec 2.4 mm implant, 237 N (±37 N) for the Osteocare 2.8 mm mini and 147 N (±25 N) for the Osteocare mini design. Other implant designs were also tested.
 
Conclusions: The diameters of the commercially available implants tested demonstrated a major impact on their ability to withstand load, with those below 3 mm diameter yielding results significantly below a value representing a risk of fracture in clinical practice. The results therefore advocate caution when considering the applicability of implants ≤3 mm diameter. Standardized fatigue testing is recommended for all commercially available implants.
植體論文
    載入全文    

BioHorizons美國植體品牌  植牙課程  植牙論文  植體產品諮詢

 

牙科論文分類


植體論文


Maintaining inter-implant crestal bone height via a combined platform-switched, Laser-Lok® implant/abutment system: A proof-of-principle canine study.

作者:M Nevins, ML Nevins, L Gobbato, HJ Lee, CW Wang, DM Kim. 
出處:Int J Periodontics Restorative Dent , Volume 33, Number 3, 2013


植體論文


Radiographic analysis of crestal bone levels around Laser-Lok collar dental implants.

作者:CA Shapoff, B Lahey, PA Wasserlauf, DM Kim.
出處:Int J Periodontics Restorative Dent. 2010;30:129-137


 

植體論文



The impact of loads on standard diameter, small diameter

 

作者:Allum SR, Tomlinson RA, Joshi R.

出處:Clin. Oral Impl. Res. 2008 May;19(6):553-559.


植體論文



Mechanical basis for bone retention around dental implants

 

作者:H Alexander, JL Ricci, GJ Hrico.

出處:J Biomed Mater Res B Appl Biomater. Volume 88B, Issue 2, Pages 306-311, Feb 2009


植體論文



Marginal tissue response to different implant neck design

 

作者:HEK Bae, MK Chung, IH Cha and DH Han.

出處:
Yonsei University College of Dentistry, Seoul, South Korea
J Korean Acad Prosthodont. 2008 Dec;46(6):602-609.


植體論文



Interactions between MC3T3-E1 cells and textured Ti6Al4V surfaces

 

作者:Soboyejo WO, Nemetski B, Allameh S, Marcantonio N, Mercer C, Ricci J. 

出處:J Biomed Mater Res. 2002 Oct; 62(1):56-72


 

植體論文



A bone-quality based implant system First year prosthetic loading


作者:Misch CE, Dietsh-Misch F, Hoar J, Beck G, Hazen R, Misch CM. 

出處:J Oral Implantol. 1999;25(3):185-197


植體論文



Five-year prospective study of immediateearly loading of fixed prostheses in completely edentulous jaws with a bone quality-based implant system

作者:Misch CE, Degidi M.

出處:Clin Implant Dent Relat Res. 2003 May;5(1):17-28


植體論文



Influence of thin mucosal tissues on crestal bone stability around implants

with platform switching a 1-year pilot study

作者:Linkevicius T, Apse P, Grybauskas S, Puisys A.

出處:J Oral Maxillofac Surg. 2010 Sep; 68(9): 2272-7.


植體論文



Influence of Laser-Lok® surface on immediate functional loading of implants in single tooth replacement a 2-years prospective clinical study.

作者:D Farronato, F Mangano, F Briguglio, V Iorio Siciliano, R Guarnieri. 

出處:Submitted for publication, Int J Periodontics Restorative Dent.


植體論文



Clinical evaluation of laser microtexturing for soft tissue and bone attachment to dental implants.

作者:GE Pecora, R Ceccarelli, M. Bonelli, H. Alexander, JL Ricci.

出處:Implant Dentistry. Volume 18(1). February 2009. pp. 57-66.


 

植體論文

Histologic evaluation of a provisional implant retrieved from man 7 months after placement in a sinus augmented with calcium sulphate a case report.

作者:G Iezzi, E Fiera, A Scarano, G Pecora, A Piattelli.

出處:Journal of Oral Implantology. Volume 33, No. 2. 2007.


植體論文

Immediate implant placement and provisionalization—two case reports.

作者:SJ Froum, SC Cho, H Francisco, YS Park, N Elian, D Tarnow.

出處:Pract Proced Aesthet Dent 2007;19(10):421-428

 

 

 

 

BioHorizons台灣植體代理

BilerChildrenLeg og SpilAutobranchen