美國植體品牌 - Marginal tissue response to different implant neck design

牙科植體

牙科植體

學術文章:
Marginal tissue response to different implant neck design.

作者:HEK Bae, MK Chung, IH Cha and DH Han.
出處:Yonsei University College of Dentistry, Seoul, South Korea   J Korean Acad Prosthodont. 2008 Dec;46(6):602-609.

摘要:
ABSTRACT

Purpose:
This animal study examined the histomorphometric variations between a turned neck (TN) implant with a RBM body, a micro-threaded (MT) neck implant and a micro-grooved (MG) implant (Laser-Lok).
 
Materials and Methods:
Mandibular premolars from four mongrel dogs were removed and left to heal for three months. One of three different implant systems were placed according to the manufacturers’ protocol and left submerged for 8 and 12 weeks. These were then harvested for histological examination. All specimens have shown uneventful healing for the duration of the experiment.
 
Results:
The histological slides have shown that all samples osseointegrated successfully with active bone remodeling adjacent to the implants. With the Laser-Lok implants, 0.40mm and 0.26mm of marginal bone loss was observed at 8 and 12 weeks respectively. The micro-threaded implants had changes of 0.79mm and 0.56mm. The machined neck implants had marginal bone level changes of 1.61mm and 1.63mm in the 8 and 12 week specimens. A complex soft tissue arrangement was observed against micro-threaded and micro-grooved implants.
 
Conclusions:
This is an animal study which looked at the marginal bone level and the soft tissue reaction between different implant systems with various neck designs. Within the limitation of this animal study the following statement can be concluded;
1. A clear morphometric difference in the bone area could not be noticed between MT and MG implant neck types.2. The BIC in MG implants were slightly higher than corresponding healing times of MT and TN implants. Higher values of the BIC could be measured in week 12 specimens than in week 8 specimens. 3. In the marginal bone level, there was marked lowering with the TN implants and least with MG implants from the reference point. There were higher marginal bone levels in week 12 than week 8 in MT and MG implants specimens but with minimal differences in TN implant specimens. 4. With MT and MG implant surfaces, the collagen alignments were not parallel to the long axis of the implants. The MT and MG implants, especially MG implants had advantageous tissue response in comparison to the turned neck implants.

 

植體論文
    載入全文    

 

牙科論文分類


植體論文


Maintaining inter-implant crestal bone height via a combined platform-switched, Laser-Lok® implant/abutment system: A proof-of-principle canine study.

作者:M Nevins, ML Nevins, L Gobbato, HJ Lee, CW Wang, DM Kim. 
出處:Int J Periodontics Restorative Dent , Volume 33, Number 3, 2013


植體論文


Radiographic analysis of crestal bone levels around Laser-Lok collar dental implants.

作者:CA Shapoff, B Lahey, PA Wasserlauf, DM Kim.
出處:Int J Periodontics Restorative Dent. 2010;30:129-137


 

植體論文



The impact of loads on standard diameter, small diameter

 

作者:Allum SR, Tomlinson RA, Joshi R.

出處:Clin. Oral Impl. Res. 2008 May;19(6):553-559.


植體論文



Mechanical basis for bone retention around dental implants

 

作者:H Alexander, JL Ricci, GJ Hrico.

出處:J Biomed Mater Res B Appl Biomater. Volume 88B, Issue 2, Pages 306-311, Feb 2009


植體論文



Marginal tissue response to different implant neck design

 

作者:HEK Bae, MK Chung, IH Cha and DH Han.

出處:
Yonsei University College of Dentistry, Seoul, South Korea
J Korean Acad Prosthodont. 2008 Dec;46(6):602-609.


植體論文



Interactions between MC3T3-E1 cells and textured Ti6Al4V surfaces

 

作者:Soboyejo WO, Nemetski B, Allameh S, Marcantonio N, Mercer C, Ricci J. 

出處:J Biomed Mater Res. 2002 Oct; 62(1):56-72


 

植體論文



A bone-quality based implant system First year prosthetic loading


作者:Misch CE, Dietsh-Misch F, Hoar J, Beck G, Hazen R, Misch CM. 

出處:J Oral Implantol. 1999;25(3):185-197


植體論文



Five-year prospective study of immediateearly loading of fixed prostheses in completely edentulous jaws with a bone quality-based implant system

作者:Misch CE, Degidi M.

出處:Clin Implant Dent Relat Res. 2003 May;5(1):17-28


植體論文



Influence of thin mucosal tissues on crestal bone stability around implants

with platform switching a 1-year pilot study

作者:Linkevicius T, Apse P, Grybauskas S, Puisys A.

出處:J Oral Maxillofac Surg. 2010 Sep; 68(9): 2272-7.


植體論文



Influence of Laser-Lok® surface on immediate functional loading of implants in single tooth replacement a 2-years prospective clinical study.

作者:D Farronato, F Mangano, F Briguglio, V Iorio Siciliano, R Guarnieri. 

出處:Submitted for publication, Int J Periodontics Restorative Dent.


植體論文



Clinical evaluation of laser microtexturing for soft tissue and bone attachment to dental implants.

作者:GE Pecora, R Ceccarelli, M. Bonelli, H. Alexander, JL Ricci.

出處:Implant Dentistry. Volume 18(1). February 2009. pp. 57-66.


 

植體論文

Histologic evaluation of a provisional implant retrieved from man 7 months after placement in a sinus augmented with calcium sulphate a case report.

作者:G Iezzi, E Fiera, A Scarano, G Pecora, A Piattelli.

出處:Journal of Oral Implantology. Volume 33, No. 2. 2007.


植體論文

Immediate implant placement and provisionalization—two case reports.

作者:SJ Froum, SC Cho, H Francisco, YS Park, N Elian, D Tarnow.

出處:Pract Proced Aesthet Dent 2007;19(10):421-428

 

 

 

 

BioHorizons台灣植體代理

BilerChildrenLeg og SpilAutobranchen