美國植體品牌 - Radiographic analysis of crestal bone levels around Laser-Lok collar dental implants

植體品牌

牙科植體

學術文章:
Radiographic analysis of crestal bone levels around Laser-Lok collar dental implants.

作者:CA Shapoff, B Lahey, PA Wasserlauf, DM Kim.
出處:Int J Periodontics Restorative Dent. 2010;30:129-137

摘要:
INTRODUCTION

This retrospective radiographic study was organized to evaluate the clinical efficacy of implants with Laser-Lok microtexturing (8- and 12-μm grooves). A physical attachment of connective tissue fibers to the Laser-Lok microtexturing on the implant collar has been previously demonstrated using human histology, polarized light microscopy, and scanning electron microscopy. This analysis of 49 implants demonstrated a mean crestal bone loss of 0.44 mm at 2 years postrestoration and 0.46 mm at 3 years. All bone loss was contained within the height of the collar, and no bone loss was evident to the level of the implant threads. The radiographic evaluation of the clinical application of this implant supports previous findings that establishing a biologic seal of connective tissue fibers around a dental implant may be clinically relevant.

植體論文
    載入全文    

 

牙科論文分類


植體論文


Maintaining inter-implant crestal bone height via a combined platform-switched, Laser-Lok® implant/abutment system: A proof-of-principle canine study.

作者:M Nevins, ML Nevins, L Gobbato, HJ Lee, CW Wang, DM Kim. 
出處:Int J Periodontics Restorative Dent , Volume 33, Number 3, 2013


植體論文


Radiographic analysis of crestal bone levels around Laser-Lok collar dental implants.

作者:CA Shapoff, B Lahey, PA Wasserlauf, DM Kim.
出處:Int J Periodontics Restorative Dent. 2010;30:129-137


 

植體論文



The impact of loads on standard diameter, small diameter

 

作者:Allum SR, Tomlinson RA, Joshi R.

出處:Clin. Oral Impl. Res. 2008 May;19(6):553-559.


植體論文



Mechanical basis for bone retention around dental implants

 

作者:H Alexander, JL Ricci, GJ Hrico.

出處:J Biomed Mater Res B Appl Biomater. Volume 88B, Issue 2, Pages 306-311, Feb 2009


植體論文



Marginal tissue response to different implant neck design

 

作者:HEK Bae, MK Chung, IH Cha and DH Han.

出處:
Yonsei University College of Dentistry, Seoul, South Korea
J Korean Acad Prosthodont. 2008 Dec;46(6):602-609.


植體論文



Interactions between MC3T3-E1 cells and textured Ti6Al4V surfaces

 

作者:Soboyejo WO, Nemetski B, Allameh S, Marcantonio N, Mercer C, Ricci J. 

出處:J Biomed Mater Res. 2002 Oct; 62(1):56-72


 

植體論文



A bone-quality based implant system First year prosthetic loading


作者:Misch CE, Dietsh-Misch F, Hoar J, Beck G, Hazen R, Misch CM. 

出處:J Oral Implantol. 1999;25(3):185-197


植體論文



Five-year prospective study of immediateearly loading of fixed prostheses in completely edentulous jaws with a bone quality-based implant system

作者:Misch CE, Degidi M.

出處:Clin Implant Dent Relat Res. 2003 May;5(1):17-28


植體論文



Influence of thin mucosal tissues on crestal bone stability around implants

with platform switching a 1-year pilot study

作者:Linkevicius T, Apse P, Grybauskas S, Puisys A.

出處:J Oral Maxillofac Surg. 2010 Sep; 68(9): 2272-7.


植體論文



Influence of Laser-Lok® surface on immediate functional loading of implants in single tooth replacement a 2-years prospective clinical study.

作者:D Farronato, F Mangano, F Briguglio, V Iorio Siciliano, R Guarnieri. 

出處:Submitted for publication, Int J Periodontics Restorative Dent.


植體論文



Clinical evaluation of laser microtexturing for soft tissue and bone attachment to dental implants.

作者:GE Pecora, R Ceccarelli, M. Bonelli, H. Alexander, JL Ricci.

出處:Implant Dentistry. Volume 18(1). February 2009. pp. 57-66.


 

植體論文

Histologic evaluation of a provisional implant retrieved from man 7 months after placement in a sinus augmented with calcium sulphate a case report.

作者:G Iezzi, E Fiera, A Scarano, G Pecora, A Piattelli.

出處:Journal of Oral Implantology. Volume 33, No. 2. 2007.


植體論文

Immediate implant placement and provisionalization—two case reports.

作者:SJ Froum, SC Cho, H Francisco, YS Park, N Elian, D Tarnow.

出處:Pract Proced Aesthet Dent 2007;19(10):421-428

 

 

 

 

BioHorizons台灣植體代理

BilerChildrenLeg og SpilAutobranchen